Centurion 3000 power converter5/24/2023 ![]() These are very old and simple units, so most unlikely to be a multistage charger with charging cycles for bulk, absorption, float, or storage. If not, Google your battery model and get a copy of the specs for your particular battery. Then compare that voltage to the specs for the battery which are usually printed on the battery. I would get a multimeter and measure the voltage when the Centurion is charging and you are reasonably sure the battery is fully charged. I am sure others will have similar but varying thoughts based on their own practcal experiences or technical training. Rectifers Dimensions: 4.25" W x 2.75" W x 11.Here are my thoughts. Range: -10˚ C to +70˚ C (maximum output power is derated above +5˚ C)Īltitude: <8,202 ft., De-rate maximum ambient temperature by 4˚ C per 3,280 ft. Logging Capacity: Periodic Log: Up to 16,384 records (dependant on number of parameters logged) Event Log: Up to 16,384 records (dependant on number of parameters logged)Ĭonnections: Relay Outputs: Mini combicon to accept 1.5mm wire USB Port: USB mini B Environmental Signal Inputs: Serial bus for rectifier control and interface to peripheral modules 6x spare general purpose inputs (analogue/digital) 2x temperature sensors (one fitted)Īlarms: Relays: 3x alarm and control relays, two of which can be mapped for customized alarm settings (expandable)Īlarm Contacts: Volt Free Contacts: 0.3A 100V (0.15A 160V) LED Indicators: Green: Power on/monitor OK Yellow: Non urgent alarm Red: Urgent alarmĪudible: 90dBA buzzer mappable to user defined conditionsĬontrols: 3x push buttons for parameter setting or viewing on front panel ![]() 100A) Monitoring and Controlĭisplay: Multi-lingual alpha numeric backlit displayĬommunications: Serial: 1x USB port on front panel for local PC interface TCP/IP: Ethernet interface for communication using SNMP protocol and internal web based configurator (optional) HTTPS capable Modbus: Supported via TCP/IP Load: Up to 12 load circuit breakers: 48 VDC 10 position 12/24 VDC 2 position (6 - 63A) Battery: Up to 2 battery circuit breakers (max. * 1kW derated to 650W 115VAC, 2kW derated to 1300W 115VAC Rated maximum System Output Power: 4000W -48V Polarity: Positive Earth Individual Rectifier Power: Voltage Range: 90-300V (derate 115 input)Įfficiency: >94% (from 30-95% output power) DC Output Specifications: Centurion III DC Power System with DC-DC Converter AC Input Preliminary specifications subject to change without notice. distribution circuit breakerĢ Centurion III Rectifiers (-48 V), 2 Centurion III DC-DC Converter Modules (48 to 12 V and/or 48 to 24V), Controller, 10 (-48V DC) and 2 (+12V or 24V DC) Circuit Breaker Distribution, 2 x 63A Battery Breakers * 30 amp maximum limit due to 30 amp max. * 120 VAC: Derate 2 kW rectifiers by 40% 1kW rectifiers by 33% Centurion III: System Configurations Rectifierġ1.4 Amps (output derated approx. All system components are sold separately. Installation in a relay rack with batteries and wiring also available. Easily configures to meet site power requirementsĬomplete system design and assembly to your application parameters: Rectifier and DC-DC configuration, circuit breaker installation, and programming of alarms and monitors.Alarm contacts monitor major system functions.Controller with digital display of up to three system DC system parameters with TCP/IP interface and SNMP monitoring/logging.Master disconnect breakers for two 48 volt battery banks, with tripped breaker alarm.1 each DC-DC converter output circuit breaker distribution with tripped breaker alarm.12 DC circuit breaker distribution capacity (48 VDC: 10 position 12/24 VDC: 2 position), with tripped breaker alarm.-48VDC circuit breaker distribution capacity with tripped breaker alarm.Output temperature compensated for precise battery charging.2 power bays accept DC-DC modules -48V to +12V and -48V to +24V.output capacity, (37 Amp, 2000 Watt, N+1) - 48 VDC 2 power bays accept 1000 or 2000 watt modular rectifiers 74 amp, 4000 watt total max.90-250 VAC input, Power Factor Corrected.19", 2U rack mount shelf with integrated power distribution.Circuit Breaker Distribution with Remote Control.Rackmount Circuit Breaker Distribution with Remote Control.Mobile Mount Inverter-Charger: Torque Series.DIN Rail Battery Detection System and DC UPS.Centurion III Power System with DC-DC Converter.NEW! Commander II / II+ -48V DC Power System.
0 Comments
Leave a Reply. |